AUSRÜSTUNG FÜR SCHIFFBAU UND INDUSTRIE
|
| VERTRETUNGEN |
| SERVICE |
| ERSATZTEILE |
| |
| EQUIPMENT FOR MARINE AND INDUSTRIAL APPLICATION |
| REPRESENTATION |
| SERVICE |
| SPARE PARTS |
 |
|
|
VENTILATORS
|

|
In 1993, Dry Air Technology brought the first portable
ventilator made of high-density polyethylene, the
VAF-3000, to the marine industry. It has been a technological
breakthrough ever since. The VAF-12E is a new and
improved version of the VAF-3000 equipped with the
same quality components as the VAF-3000 but with a
few minor aesthetic changes. It is no wonder why the
VAF-12E is the marine professional’s top choice
for confined space ventilation, exhausting fumes and
spot cooling.
|
|

|
| Performance-Ventilator Type: VAF-12E (Axial) |
Housing
Voltage
Power
Blower
Duct fit
Power supply
Dimension
Weight
|
: dual wall polyethylene shell, blue
: 230 VAC 50/60 Hz
: 0,75 KW
: 60 m³ / min (3600 m³/h)
: both sides 300 mm
: 5 m with plug
: 533 x 355 x 430 mm
: 16 kg
|
|
| Performance-Ventilator Type: VAF-12P FRL (Axial) |
Housing
Current
Power
Blower
Duct fit
Dimension
Weight
|
: dual wall polyethylene shell, blue
: air driven
: 1,10 KW
: 58 m³ / min (3500 m³/h)
: both sides 300 mm
: 533 x 355 x 430 mm
: 16 kg
|
|
|
|

|
| Performance-Ventilator Type: VAF-16E (Axial) |
Housing
Voltage
Power
Blower
Duct fit
Power supply
Dimension
Weight
|
: dual wall polyethylene shell, red
: 230 VAC 50/60 Hz
: 0,75 KW
: 126 m³ / min (7560 m³/h)
: both sides 400 mm
: 5 m with plug
: 560 x 533 x 406 mm
: 17,2 kg
|
|
| Performance-Ventilator Type: EFi85xx (Axial) ex-proof |
Housing
Protection class
Voltage
Power
Blower
Duct fit
Power supply
Dimension
Weight
|
: glass-reinforced anti static ABS housing, black
: EEx d 11B T4
: 230 VAC 50 Hz
: 0,64 KW
: 62,5 m³ / min (3750 m³/h)
: both sides 300 mm
: 10m power cord with explosion proof plug IEC 309 204V EEx de
: 410 x 380 x 410 mm
: 20 kg
|
|

|
|

|
| Performance-Ventilator Type: EFi75xx (Axial) ex-proof |
Housing
Protection class
Voltage
Power
Blower
Duct fit
Power supply
Dimension
Weight
|
: glass-reinforced anti static ABS housing, black
: UL Class I-Group D UL Class II-Group E, F, G
: Available 115V/230V, 50Hz/60Hz
: 0,64 KW
: 70,8 m³ / min (4250 m³/h)
: both sides 300 mm
: 9 m power cord
: 406 x 381 x 406 mm
: 20 kg
|
|
| Performance-Ventilator Type: AFi75xx (Axial) ex-proof |
Housing
Current
Power
Blower
Duct fit
Power supply
Dimension
Weight
|
: glass-reinforced anti static ABS housing, black
: air driven
: 0,64 KW
: 57,8 m³ / min (3470 m³/h)
: both sides 300 mm
: 10m power cord with explosion proof plug IEC 309 204V EEx de
: 410 x 430 x 410 mm
: 14 kg
|
|

|
|

|
Type CIS Duct 300/5m, colour black - length 5m / 150mm / -20°- +80°C |
|
Welded, tear-proof, polyester-tissue coated with PVC,
with tensile steel spring encased in thick abrasion
protection, fire resistant and antistatic. Additional
final rings and hanging eyes at steel springs. All ducts
will be delivered with one hose clamp for save
connection to VAF12E
|
|
| Type CIS-Coupler 300mm |
|
For easy connection of duct to duct the coupler is to
install over the final rings of the duct. No metal
coupler is needed. Fans and hoses can get connected to
each other in an arbitrary order.
|
Download:
Technical Informations (pdf - ca 290 KB)
|

Back to Products
|
|